Square D QO 200A Double-Pole Standard Trip Main Breaker

Category Main Breaker
 
P
516686

Square D QO 200A Double-Pole Standard Trip Main Breaker

Item Code: 516686
Category Main Breaker
  • Field installable main breaker for QO and newer models of Homeline load centers with straight in feed
  • Compatible with QO and Homeline load centers, CSED devices, and NQOD panel boards rated for 100A to 125A
  • 200, 2-Pole
  • ANSI/UL Listed
Field installable main breaker for QO and newer models of Homeline load centers with straight in feed. Protects breaker panel in a load center. Used for overload and short-circuit protection of electrical systems. Compatible with QO and Homeline load centers, CSED devices, and NQOD panel boards rated for 100 to 125 amps. ANSI (American National Standards Institute) certified and UL (Underwriter's Laboratories) listed for 120 volt/240 volt and 22,000 AIR.
Weight

2.8lb

Height

2.3in

Width

3.5in

Length

3.85in

Amperage

200

Brand

Square D

Category

Main Breaker

Certification

ANSI/UL Listed

Depth

2.91 In.

Frame Size

2-Space

Height

3.50 In.

Interruption Type

Standard Trip

Mount Type

Bolt-on

Number Of Poles

2-pole

Voltage

120/240

Width

2.5 in.

Wire Size

#4 AWG to 300 KCMIL

Call for Availability
Compare

Square D QO 200A Double-Pole Standard Trip Main Breaker

Category Main Breaker
 
P
516686

Square D QO 200A Double-Pole Standard Trip Main Breaker

Item Code: 516686
Category Main Breaker
  • Field installable main breaker for QO and newer models of Homeline load centers with straight in feed
  • Compatible with QO and Homeline load centers, CSED devices, and NQOD panel boards rated for 100A to 125A
  • 200, 2-Pole
  • ANSI/UL Listed
Call for Availability
Compare
Field installable main breaker for QO and newer models of Homeline load centers with straight in feed. Protects breaker panel in a load center. Used for overload and short-circuit protection of electrical systems. Compatible with QO and Homeline load centers, CSED devices, and NQOD panel boards rated for 100 to 125 amps. ANSI (American National Standards Institute) certified and UL (Underwriter's Laboratories) listed for 120 volt/240 volt and 22,000 AIR.
Weight

2.8lb

Height

2.3in

Width

3.5in

Length

3.85in

Amperage

200

Brand

Square D

Category

Main Breaker

Certification

ANSI/UL Listed

Depth

2.91 In.

Frame Size

2-Space

Height

3.50 In.

Interruption Type

Standard Trip

Mount Type

Bolt-on

Number Of Poles

2-pole

Voltage

120/240

Width

2.5 in.

Wire Size

#4 AWG to 300 KCMIL

SEARCH ×